  Datasheet File OCR Text:
 AC-DC
90 Watts AMM90 Series
* * * * * * *
xppower.com
CEC2008 & EISA2007 Compliant 12V Worldwide Medical Approvals Small Size/High Power Density Class I and Class II Versions Operating Temperature up to +60 C High Efficiency Locking Output Connector 15 V
Specification
Input
Input Voltage Input Frequency Input Current * 90-264 VAC * 47-63 Hz * 1.2 A rms at 115 VAC, 0.6 A rms at 230 VAC Inrush Current * 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 C Power Factor * 0.98 typical Earth Leakage Current * 90 A max at 115 VAC/60 Hz, (Class I Versions) 150 A max at 230 VAC/50 Hz Input Protection * Internal 2.5 A fuse in live & neutral lines
General
Efficiency Isolation * 78% min for 5 V, 6 V & 9 V models 85% minimum for all others * 4000 VAC Input to Output 1500 VAC Input to Ground (Class I only) 500 VAC Output to Ground (Class I only) * 50-110 kHz variable * 3.4 W/In3 * 150 kHrs per MIL-HDBK-217F
Switching Frequency Power Density MTBF
Environmental
Operating Temperature * 0 C to +60 C, derate from 100% power at +40 C to 50% power at +60 C Cooling * Convection-cooled Operating Humidity * 10-95% RH, non-condensing Storage Temperature * -20 C to +80 C Operating Altitude * 3000 m Shock * 30 g, 10 ms on 3 axes Vibration * 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
Output
Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response 5 to 48 VDC Not user-adjustable 2 % No minimum load required 2 s max at 115 VAC <80 ms at 115 VAC 15 ms minimum at full load & 115 VAC 0.5% maximum See table 4% max. deviation, recovery to within 1% in 500 s for a 25% load change Ripple & Noise * 2% max pk-pk (see note 1) Overvoltage Protection * 112-140% Vnom, recycle input to reset Overtemperature * Unit shuts down, auto recovery Protection Overload Protection * 110-200%, auto recovery Short Circuit Protection * Trip and restart (Hiccup mode) Temperature * 0.04%/C Coefficient * * * * * * * * * *
EMC & Safety
Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions * EN55011/FCC/VCCI, Class B conducted EN55011/FCC/VCCI, Class B radiated * EN61000-3-2, Class A * EN61000-3-3 * EN61000-4-2, level 3 Perf Criteria A * EN61000-4-3, level 2 Perf Criteria A * EN61000-4-4, level 3 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, 3 V Perf Criteria A * EN61000-4-8, 3 A/m Perf Criteria A * EN61000-4-11, 70% UT for 10 ms, 40% UT for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B (Perf Criteria A, A, B with 70% load) * EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, CE Mark
Safety Approvals
AC-DC
Models and Ratings
Output Power 60 W 60 W 70 W 80 W 85 W 85 W 90 W 90 W 90 W 90 W 90 W Notes
1. 2. 3. 4. Ripple and noise measured at 20 MHz bandwidth with a 10 F tantalum and 0.1 F ceramic cap connected at the measurement point. Total regulation includes initial set accuracy, line and load regulation. For class II versions, add `C2' to model number e.g. AMM90PS24C2. For optional Barrel Jack Connector, add `B1' to model number e.g. AMM90PS24C2B1 (not available on 5 V or 6 V models).
AMM90
Output Voltage 5.0 V 6.0 V 9.0 V 12.0 V 13.5 V 15.0 V 18.0 V 19.0 V 24.0 V 30.0 V 48.0 V Output Current 12.00 A 10.00 A 7.78 A 6.67 A 6.30 A 5.67 A 5.00 A 4.74 A 3.75 A 3.00 A 1.87 A Total Regulation(2) 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Model Number(3, 4) AMM90PS05 AMM90PS06 AMM90PS09 AMM90PS12 AMM90PS13 AMM90PS15 AMM90PS18 AMM90PS19 AMM90PS24 AMM90PS30 AMM90PS48
Mechanical Details
Cable length approx 48" (1219mm)
1.72 (43.7)
Rubber foot (4 places.)
1
3
2
4
PIN CONNECTIONS PS09 - PS48 Pin Function 1 Return 2 Output+ 3 Return 4 Output+ PIN CONNECTIONS PS05 - PS06 Pin Function 1 Return 2 Return 3 Output+ 4 Return 5 Output+
5.12 (130.0)
3
5 2
1
4
Optional Barrel Jack Connector
0.433 (11.0) 0.217 (5.5)
3.00 (76.2)
0.083 (2.1)
0.413 (10.5)
0.02 (0.5) AC Input IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version
Notes
1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Maximum load per pin on output connector is 7.5 A. 3. Output connector for AMM90PS05 and PS06 is 5 pin 180 DIN. 4. Output connector for AMM90PS09-PS13 is KYCON KPP-4P non locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 5. Output connector for AMM90PS15-PS48 is KYCON KPP-4P locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 7. Weight: 1.46 lb (660 g).
15-Dec-08


▲Up To Search▲   

 
Price & Availability of AMM90PS05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X